Borehole «Kapp Linne 1» (at site «Svalbard », Svalbard) active

{JSON}

Permafrost Setting

Permafrost Thickness m
Permafrost Zone Continuous

Environmental Setting

Vegetation Type No Vegetation
Vegetation No vegetation
Hydrology
Landform
Lithology The entire hole is through bedrock. Possible to dig down c. 30cm in weathered ... [more]
Morphology Plain. Local relief: 5m
Description
Slope
Aspect 306°
Prior Records Datalogger ; Start date ; End date ; Unit of measure ; Measure range Geoprecision ; ... [more]

Description

The entire hole is through bedrock. Possible to dig down c. 30cm in weathered rock. ... [more]

Measurement Method

Drilling

Drilling Method Hammer Drilling
Date Drilled 2008-01-01
Depth 30 m
Drilling Angle 90°
Diameter 3.2 cm
Deepest Sensor 30 m

Accessibility

Type Boat
Distance From Road m

Disturbance(s)

Disturbance Lake
Distance 100 m
Disturbance (Other)
Distance m

Contact(s)

Responsible Person
Hanne Hvidtfeldt Christiansen
Professor , Physical geography
The University Centre in Svalbard (UNIS)
Norway

Location

Elevation: 18.5 m.a.s.l.
Latitude, Longitude: 78.05663°, 13.64148°
n/a

How to cite this borehole

Hanne Hvidtfeldt Christiansen , Alvar Braathen , Fabrice Caline, Bernd Etzelmüller , Herman Farbrot, Ketil Isaksen , Lene Kristensen , Rune S. Ødegård : Permafrost Temperature (PT) at «Kapp Linne 1» (Svalbard). Code: KL-B-1, GTN-P PID: pt/57.
n/a
n/a
n/a
Entry created: 2024-08-21 12:14, Entry last modified: 2026-05-15 11:42 – Time Zone: UTC/GMT +01:00
Frequency Data Type Medium Unit Method Accuracy Quality Start End Link Download
Ground Temperature
6 hours Continuous Soil °C Thermistor Automated 0.1 °C Controlled 2008-09-23 2020-09-15 view CSV NetCDF

By downloading data from GTN-P, you agree to the Data Policy (CC BY 4.0). Data are provided “as-is” without warranties. Users are responsible for their own interpretations and should follow accepted scientific standards. See full Disclaimer. Please cite the data as described in the Data Policy.

Statistics & additional information

Description Temperature-time data series with measurements at 0.00, 0.25, 0.50, 0.75, 1.00, 1.50, ... [more]
Min. Value -23.91 °C
Max. Value 18.93 °C
Avg. Value -2.59 °C
No. of Data Points 366,870
No. of NULL Values 111 (0.03 %)
Max. Depth 29 m
No. of Sensors 21
Entry created: 2024-08-21 14:17, Entry last modified: 2024-12-11 13:05